DGH7.1.2007
Hamilton Home Products, Inc.
1-800-879-0123
Installation and Maintenance Instructions
for Commercial and Residential Use
Gas-Fired Unit Heaters DGH 30 – 75
FOR YOUR SAFETY
WHAT TO DO IF YOU SMELL GAS:
Open windows.
Do not try to light any appliance.
Do not touch any electrical switch;
do not use any phone in your
building.
Immediately call your gas supplier
from a neighbor’s phone. Follow
the gas supplier’s instructions.
If you cannot reach your gas
supplier, call your fire department.
FOR YOUR SAFETY
Do not store or use gasoline or other
flammable vapors and liquids in the vicinity of
this or any other appliances.
WARNING
Improper installation, adjustment, alteration,
service or maintenance can cause injury or
property damage. Refer to this manual. For
assistance or additional information consult a
qualified installer, service agency or gas
supplier.
CAUTION
To prevent premature heat exchanger failure
do not located ANY
gas-fired units in areas
where chlorinated, halogenated, or acid
vapors are present in the atmosphere.
WARNING
Improper installation, adjustment, alteration,
service or maintenance can cause property
damage, injury or death, and could cause
exposure to substances which have been
determined by various state agencies to cause
cancer, birth defects or other reproductive
harm.
WARNING
All installation and service for this series of
heaters MUST be performed by a qualified
service agency or technician.
Please leave this manual with the owner.
Explain operation of the unit to the owner.
PLEASE NOTE: This unit comes with a grounded plug requiring a dedicated electrical
outlet with the proper polarity on its own circuit breaker. If the burners do not stay lit,
verify the polarity of the outlet.
DO NOT RETURN E
Q
IPMENT TO THE RETAILER. CONTACT HAMILTON AT 1-800-879-0123.
Seitenansicht 0
1 2 3 4 5 6 ... 21 22

Inhaltsverzeichnis

Seite 1 - DGH7.1.2007

DGH7.1.2007 Hamilton Home Products, Inc. 1-800-879-0123 Installation and Mainte

Seite 2

3.) Venting system shall terminate a minimum of 9.) Figure 4 shows how to vent piping through3 ft. (.9m) above any forced system located a combustible

Seite 3

A regulator is required on the propane tanks.Check inlet supply pressure at the unit and Piping must be gas tight and a non-hardeningupstream of the

Seite 4

meter, making sure all other appliances are If the regulator needs adjustment, the regulator turned off. adjusting screw may be turned clockwise toThe

Seite 5 - COMBUSTION AI

7. Restart heater by following the light instructions. Electrical ConnectionsSet thermostat to the desired temperature setting.Tabel 6 Manifold Pre

Seite 6 - WARNING

FIGURE 8 DGH WIRING DIAGRAM BEFORE OPERATING UNIT HEATERFollow these on-site pre-operational proceduresbefore putting unit heater into operation:1. T

Seite 7

C. Use only your hand to move the gas controlswitch. Never use tools. If the switch will not move by hand, don't try to repair it, call a quali

Seite 8

TECHNICAL / DIMENSIONS DIMENSIONS (inches / cm)FOR DGH (30, 45, 60, 75) MODELS 30 45 60 75A 26.8 / 68.1 26.8 / 68.1 26.8 / 68.1 26.8 / 68.1B 12.2 / 3

Seite 9

MAINTENANCE 13. Turn gas and electricity back on and set the thermostat high enough to cycle the unit to go 1. Remove the access panel. through a comp

Seite 10 - Based on a 160˚F (70.4˚C)

SAFETY DEVICES (Continued) LED DIAGNOSTIC CAPABILITY3) Pressure Switch The red LED on the ignition module indicates theThis is a normally open type sw

Seite 12 - (Seconds) 5 Ft³

UNPACKING AND INSPECTION WARNINGS1. Examine unit as received for any Should over heating occur, or the gas damages. If any

Seite 13 - PLEASE NOTE

WINCHESTER Garage Heater Parts ListingRef # Description DGH 30 DGH 45 DGH 60 DGH 751 Casing Wrapper GH-1001 GH-1001 GH-1025 GH-10252 Cover Panel* GH-1

Seite 14 - PROPER POLARITY IS REQUIRED

BL 1 G.V. HOT (24 V)Y 2 PR. SW.3 T-STAT ( W )YRBK BK 5 FAN HOT (F1)BK 6 120 V (L1)L1 Y Y 7 24 V ( R )8 GROUNDL2 BL BL10 ING. (S1)W W 11

Seite 15

1-Year Part Warranty / 10-Year Heat Exchanger Warranty ADAMS LIMITED WARRANTY Adams, manufacturer of WINCHESTER brand garage heaters, referred to as

Seite 16 - 45 60 75

7. Do maintain a rear clearance of 18" 18. Do not attach duck work, air filters or(45.7cm) or 6" (15.2cm) beyond motor at plastic vent pipe

Seite 18 - ADDENDUM - Page 18

SUSPENSION washers and lock nuts, lock washers and nuts, or a double nut arrangement similarity used on Unit(s) must be supported from the structural

Seite 19

The requirements for combustion and ventilation This unit heater series is equipped with powerair depends on how unit will be installed. That is exha

Seite 20 - ** MODELS USE TWO

7. If improper venting is observed during any Unit heaters come with the vent adaptor alreadyof the above tests, the venting system must attached so t

Seite 21 - Unit Wiring Diagram

Figure 3B HORIZONTAL THROUGH vented into a masonry (or concrete) chimneyCOMBUSTIBLE WALLlined with material acceptable with recog-nized standards an

Seite 22

Figure 4 Horizontal Venting With Upward C.) Requirements For Horizontal VentingPitch1. Horizontally Vented heaters perform as Category III Applianc